Operator's Manual
ThedecalontheSCMonlyincludessymbols.Three
LEDoutputsymbolsareshownintheoutputbox.All
otherLED’sareinputs.Thechartbelowidentiesthe
symbols.
Figure28
HerearethelogicaltroubleshootingstepsfortheSCM
device.
1.Determinetheoutputfaultyouaretryingtoresolve
(PTO,START,orETR).
2.MovekeyswitchtotheOnpositionandensurethat
theredpowerLEDisilluminated.
3.MoveallinputswitchestoensureallLED’schange
state.
4.Positioninputdevicesatappropriatepositionto
achievetheappropriateoutput.Usethefollowing
logiccharttodeterminetheappropriateinput
condition.
5.IfspecicoutputLEDisilluminatedwithout
appropriateoutputfunction,checkoutputharness,
connections,andcomponent.Repairasrequired.
6.IfspecicoutputLEDisnotilluminated,check
bothfuses.
7.IfspecicoutputLEDisnotilluminatedandinputs
areinappropriatecondition,installnewSCMand
determineiffaultdisappears.
Eachrow(across)inthelogicchartbelowidenties
inputandoutputrequirementsforeachspecicproduct
function.Productfunctionsarelistedintheleft
column.Symbolsidentifyspeciccircuitcondition
including:energizedtovoltage,closedtoground,and
opentoground.
INPUTSOUTPUTS
FunctionPower
ON
In
Neutral
StartON
Brake
ON
PTOONInSeat
HiT empBacklap
Start
ETR
PTO
Start
——
+
OO
—
OO
++
O
Run(Off
Unit)
——
OOOOOOO
+
O
Run(On
Unit)
—
OO
—
O
—
OOO
+
O
Mow
—
OO
———
OOO
++
Backlap
——
OO
—
OO
—
O
++
HiT emp
—
O
—
OOO
•(–)Indicatesacircuitclosedtoground.–LEDON
•(O)Indicatesacircuitopentogroundor
de–energized–LEDOFF
•(+)Indicatesanenergizedcircuit(clutchcoil,
solenoid,orstartinput)LEDON.
•ABlankindicatesacircuitthatisnotinvolvedwith
thelogic.
28