13. Clamp the inner pinion bearing with a universal
bearing remover (Fig. 32). Position the unit in a press
and carefully push the drive pinion out of the bearing.
DO NOT allow the pinion to drop on the floor - damage
will r
esult.
Figure 32
14. To remove the outer pinion bearing cup, position the
housing in a press. Place a press plate of the proper
size against the cup. Press the cup out of the housing
(Fig. 33).
Figure 33
15. Position the front housing on a press bed with the
bearing saddles resting on the press bed. Protect the
bearing saddles with a strip of wood if the press bed is
rough.
Insert a press plate of the proper size and press the
b
earing cup toward the inside of the housing. Retain the
shims located under the bearing cup (Fig. 34). If the
shims are damaged, replace with new shims of the
same thickness.
Figure 34
Groundsmaster
®