Service Manual
OperatorAdvisories
CAUTION
Removealljewelry,especiallyringsandwatches,beforedoingany
electricaltroubleshootingortesting.Also,disconnectthebattery
cablesunlessthetestrequiresbatteryvoltage.
Foreffectivetroubleshootingandrepairs,youmusthaveagoodunderstanding
oftheelectricalcircuitsandcomponentsusedonthismachine(seeAppendixA
(pageA–1)).
Ifthemachinehasanyinterlockswitchesby−passed,reconnecttheswitchesfor
safetyandefcienttroubleshooting.
Note:ChecktheInfoCenterDisplayforpossibleoperatoradvisoriesorfaults
wheneverdiagnosingmachineelectricalproblems.
ThelistbelowidentiestheoperatoradvisoriesthataregeneratedbytheTEC
controller.AnadvisorywillbedisplayedontheInfoCenterDisplay.Typically,an
advisorycanbeeliminatedwithachangeinmachinecontrolsbytheoperator.
AdvisoryAdvisoryDescription
160Inhibitstart
161
InhibitPTO
162Inhibitcuttingunitlower
163
InhibittractionHIGHspeedrange
164
InhibittractionLOWspeedrange
165Inhibittraction
166Inhibitcruisecontrol
167Deratetractionsetting
168
Inhibittractionteach(tractionpedalcalibration)
169Engineshutdown
170
Recyclekeyswitch(keyswitch)
171Autoidleengaged
172
Calibrate(tractionpedal)
173
Masteraddressclaim(frontTECcontroller)
174
Slaveaddressclaim(rearTECcontroller)
175Derateengine
180Masterrestart
183Regencomplete
184
Regenfailed
185Regenrequired
186
Regensetfullthrottle
188Parkedregenrequired
Groundsmaster
®
4100-D&4110-D
Page3–9Troubleshooting:
13203SLRevF