Service Manual

TractionPedalPositionSensorCalibration(continued)
ADVISORY #172
Calibrate Teach Is
Engaged
g275988
Figure178
4.UsetheInfoCenterDisplayServicemenu(seeInfoCenterDisplay(page
6–7))toobtainandselecttheTractionPedalmenuitem.TheInfoCenter
displayshouldindicatethatthetractionpedalcalibrationprocessisengaged
(Figure178).
5.FollowthepromptsontheInfoCenterdisplayscreentocalibratethetraction
pedalpositionsensor.Thecalibrationstepsarelistedbelow:
A.Slowlypresstractionpedaltotheforwarddirection.
B.Pressandholdtractionpedaltothefullforwardposition.
C.Allowtractionpedaltoreturntotheneutralposition.
D.Slowlypresstractionpedaltothereversedirection.
E.Pressandholdtractionpedaltothefullreverseposition.
ADVISORY #172
Calibrate. Exit Good
g275989
Figure179
F.CheckthatInfoCenterdisplayindicatesasuccessfulcalibrationprocess
(Figure179).
6.TurnkeyswitchtoOFFwhichexitsthetractionpedalcalibrationmenu.
ElectricalSystem:Adjustments
Page6–24
Groundsmaster
®
4100-D&4110-D
13203SLRevF