Fig 756 PICT-6644
22. Remove the 4 bolts, spacers and the hydro control
shield from the frame (Fig. 756).
Fig 755 PICT-6642
21. Remove the 4 nuts from the bolts securing the hydro
control shield to the frame (Fig. 755).
Fig 758 PICT-6652
24. To access the control shaft set screw, maneuver the
shaft side of the pump out of the hole in the frame
and tilt it toward the front of the machine. Loosen the
set screw by inserting a wrench through the opening
in the side of the chassis (Fig. 758).
Fig 757 PICT-6649
23. Rotate the case drain hose tting to gain access to
the set screw on the control shaft (Fig. 757).