Lift/LowerCircuitProblems
Problem
PossibleCauses
Thegearpumpisnoisy(cavitation).Thehydraulic-uidlevelinthehydraulictankislow.
Thehydraulicuidisverycold.
Thesuctionlineisrestricted.
Thereareairleaksinthesuctionline.
Thecuttingdeck(orimplement)doesnotliftorliftsslowly.
Theenginespeedistoolow.
Theliftcylinderlinkageisbindingorbroken.
Theliftarmbushingsarebinding.
Thehydraulic-uidlevelinthehydraulictankislow.
Thegearpumppressureorowisinsufcient.
Thegearpumpisdamaged.
Theimplement-reliefvalve(inthegearpump)isstuckopen.
Theliftcylinderisleakinginternally.
Theliftcontrolmanifoldisdamaged.
Thecuttingdeck(orimplement)raises,butdoesnotstayup.Theliftcylinderisleakinginternally.
Theliftcontrolmanifoldiswornordamaged.
HydraulicSystem:Troubleshooting