Service Manual
HydraulicSolenoidValveCoils
FRONT
RIGHT
2
3
1
4
g276029
Figure220
1.FrontPTOmanifold3.LHPTOmanifold
2.RHPTOmanifold4.Combinationmanifold
Severalhydraulicsolenoidvalvecoilsareusedonthehydrauliccontrolmanifolds
ofGroundsmaster4100−Dand4110−Dmachines.WhenenergizedbytheTEC
controller,thesecoilsprovidehydrauliccircuitcontrol.
Solenoidvalvecoilswithtwo(2)differentresistancespecicationsareusedon
the4100−Dand4110−D.Thecorrectresistanceofacoilcanbeidentiedby
measuringtheheightanddiameterofthecoil(Figure221).Resistancetestingof
thecoilscanbedonewiththecoilremainingonthehydraulicvalve.
Note:Toassistintroubleshooting,identicalsolenoidcoilscanbeexchanged.If
theproblemfollowstheexchangedcoil,aproblemwiththecoillikelyexists.If
theproblemremainsunchanged,somethingotherthanthesolenoidcoilisthe
problemsource(e.g.switch,circuitwiring,hydraulicproblem).Refertoyour
PartsCatalogtodetermineifsolenoidcoilsareidentical.
ElectricalSystem:ComponentTesting
Page6–66
Groundsmaster
®
4100-D&4110-D
13203SLRevF