TractionPedalPositionSensorCalibration
1
2
g275987
Figure177
1.Tractionpedal2.Pedalpositionsensor
IMPORTANT
Aproperlyinstalledandcalibratedtractionpedalpositionsensoris
criticaltoaccuratetractionsystemresponseandforreliablesensor
life.Usecarewhenremoving,installingandcalibratingthetraction
pedalpositionsensor.
CalibrationofthetractionpedalpositionsensorensuresthattheTECcontroller
canidentifythetractionneutral,forwardandreversepositions.
1.Parkmachineonalevelsurface,lowercuttingdecks,engageparkingbrake
andstopengine.
2.TurnkeyswitchtoRUNbutdonotstartengine.
3.UsetheInfoCenterDisplaySettingsmenu(seeInfoCenterDisplay(page
6–7))toobtainandselectProtectedMenus.EntervalidPINforthemachine
toallowaccesstoprotectedmenuitemsincludingcalibrationofthetraction
pedalpositionsensor.TheInfoCenterdisplayscreenshouldindicate“PIN”in
theupperrighthandcornerwhenthecorrectPINnumberhasbeenentered.
Groundsmaster
®
4100-D&4110-D
Page6–23
ElectricalSystem:Adjustments
13203SLRevE