Service Manual
FaultsScreen
1
3
5
3
4
Faults
#39
Clear System Faults
−57.3 Ago
2
5
g275694
Figure166
1.Faultmenu
4.Choosemenuitem
2.Faultitems5.Backbutton
3.Movetomenuitems
Thefaultsscreen(Figure166)willlistallmachineelectricalfaultsthathave
occurredsincethefaultswerelastclearedfromtheInfoCenter.Thefaultswill
beidentiedbyafaultnumberandwhenthefaultoccurred.Faultsthatmight
occuronthemachinearelistedinFaultCodesintheTroubleshootingsectionof
thischapter.
AfterentryofthePINcode,theInfoCenterfaultlogcanbeclearedbyselecting
theclearsystemfaultsmenuitem.Theclearedfaultswillberemovedfromthe
Info-CenterlistbutwillberetainedintheTECcontrollermemory.
Ifafaultoccursduringmachineuse,theremaybeachangeinmachine
functionalityduetothefault.Shouldtherebemachineoperationissuesdue
toafault,arststeptoremedytheissuewouldbetodisengagethecutting
decks,releasethetractionpedal,turnthekeyswitchOFFandallowallmachine
functionstostop.Then,attempttorestartthemachinetoseeifoperationhas
returnedtonormal.Somefaultswillberesetduringtherestartandwillthen
allownormalfunction.Ifafaultcontinuestooccur,furthersystemevaluationand
possiblecomponentrepairorreplacementwillbenecessary.
Toreturntothemainmenuscreenfromthefaultsscreen,pressthebackbutton
(leftbutton).
ElectricalSystem:GeneralInformation
Page6–12
Groundsmaster
®
4100-D&4110-D
13203SLRevE