Service Manual

RemovingtheBlowerFan(continued)
CAUTION
Looseninganyairconditioningsystemttingorcomponentallows
thepressurizedrefrigeranttoescape,causingpossibleinjury.
Donotloosenanysystemttingorcomponentuntilacertiedair
conditioningservicetechniciandischargesthesystemcompletely.
4.Haveacertiedairconditioningservicetechnicianevacuatetherefrigerant
fromtheairconditioningsystem.
5.Disconnectbothevaporatorcoreswivelttingsfromfrontportsofexpansion
valve.Immediatelycaptubesandexpansionvalveportstopreventmoisture
andcontaminantsfromenteringthesystem.Positionexpansionvalvewith
attachedhosesawayfromthemixingbox.
g279106
Figure373
1.Freezeswitch
4.T erminal3(orange)
2.MINterminal(violet)5.Groundterminal(black)
3.T erminal2(brown)
6.Labelheaterhosesforassemblypurposes.Loosenhoseclampsand
disconnectbothheaterhosesfromtubesonheatercore.
7.Removethemixingboxcoverasfollows:
A.Carefullyuseasmallprybartoraisetheheadofthepininthecenterof
eachrivetthatsecuresthemixingboxcover.
B.Lifttherivetsfromthecoverandmixingbox.
C.Removethemixingboxcover.
8.Notethelocationofthewireharnessconnectorsonthefreezeswitchand
blowerfanassembly(Figure373),disconnectthewireharnessconnectors
fromtheswitchandfan.
9.Carefullyraisetheheatercore/airconditioningevaporatorassemblywith
attachedblowerfanfromthemixingbox.
10.Removethe6screws(item9inFigure372)thatsecuretheblowerfantothe
heatercore/airconditioningevaporatorassembly,andremovetheblowerfan.
Groundsmaster
®
4000-D&4010-D
Page11–27
OperatorCab
(Formodels30635and30636)
:ServiceandRepairs
13202SLRevF