Service Manual

Table Of Contents
Installation(Figure96andFigure97)(continued)
8.Fillpistonpumphousingthroughcasedrain(90ºbarbedtting)withnew
hydraulicoil(Figure99).Thiswillensurethatinternalpumpcomponents
haveadequatelubricationduringinitialoperation.
9.Lowermachinetoground.
10.Replacehydraulicltersandllhydraulicreservoirwithnewhydraulicoil.
11.Primehydraulicpumps(seePrimingHydraulicPumps(page5–86)).
12.Properlyllhydraulicsystem(seeChargeHydraulicSystem(page5–91)).
13.Stopengineandcheckforhydraulicoilleaks.Checkhydraulicreservoir
oillevel.
Groundsmaster
®
4100-D&4110-D
Page5–101
HydraulicSystem:ServiceandRepairs
13203SLRevG