Service Manual

Groundsmaster 360 Page 5 − 5 Electrical System
(Rev. A)
Battery Terminal Protector
Aerosol spray that should be used on battery terminals,
ring terminals and fork terminals to reduce corrosion
problems. Apply terminal protector to the connection af-
ter the battery cable, ring terminal or fork terminal has
been secured.
Toro Part Number: 107−0392
Figure 4
Dielectric Gel
Dielectric gel should be used to prevent corrosion of un−
sealed connection terminals. To ensure complete coat-
ing of terminals, liberally apply gel to both component
and wire harness connector, plug connector to compo-
nent, unplug connector, reapply gel to both surfaces and
reconnect harness connector to component. Connec-
tors should be thoroughly packed with gel for effective
results.
Do not use dielectric gel on sealed connection terminals
as the gel can unseat connector seals during assembly.
Toro Part Number: 107−0342
Figure 5
Battery Hydrometer
Use the Battery Hydrometer when measuring specific
gravity of battery electrolyte. Obtain this tool locally.
Figure 6
Electrical
System