Operator's Manual

ServicingtheAirCleaner
ServiceInterval:Every400hours
Note:Ifthefoamgasketinthecoverisdamaged,
replaceit.
Important:Avoidusinghigh-pressureair,which
couldforcedirtthroughthelterintotheintake
tract.
Important:Donotcleantheusedltertoavoid
damagetotheltermedia.
Important:Donotuseadamagedlter.
Important:Donotapplypressuretotheexible
centerofthelter.
g243913
Figure33
ServicingtheEngine-Oil
CheckingtheEngine-OilLevel
ServiceInterval:Beforeeachuseordaily
Theengineisshippedwithoilinthecrankcase;
however,checktheoillevelbeforeandafteryourst
starttheengine.Checktheoillevelbeforeoperating
themachineeachdayoreachtimeyouusethe
machine.
Thecrankcasecapacityisapproximately3.8
L(4quarts)withthelter.Usehigh-qualityengineoil
thatmeetsthefollowingspecications:
APIClassicationLevelRequired:CH-4,CI-4or
higher.
Preferredoil:SAE15W-40(above0°F(-17°C)
Alternateoil:SAE10W-30or5W-30(all
temperatures)
Note:ToroPremiumEngineoilisavailablefromyour
distributorineither15W-40or10W-30viscosity.See
thepartscatalogforpartnumbers.
1.Parkthemachineonalevelsurface,lowerthe
cuttingunit,movethethrottlelevertotheSLOW
position,shutofftheengine,andremovethekey
fromtheignitionswitch.
2.Openthehood.
3.Removethedipstick,wipeitclean,installthe
dipstickintothetube,andpullitoutagain.
4.Checktheengine-oillevel.
Iftheoilisbetweenthemarksonthedipstick
(FofFigure34),theengineoilisatasufcient
level.Iftheoilisbelowthelowermarkonthe
dipstick(BofFigure34),addmoreoiluntilthe
oillevelisbetweenthemarksonthedipstick.
39