Operator's Manual
WARNING
Incorrectbatterycableroutingcoulddamagethe
machineandcablescausingsparks.Sparkscan
causethebatterygassestoexplode,resultingin
personalinjury.
•Alwaysdisconnectthenegative(black)battery
cablebeforedisconnectingthepositive(red)
cable.
•Alwaysconnectthepositive(red)batterycable
beforeconnectingthenegative(black)cable.
StoringtheBattery
Ifthemachinewillbestoredmorethan30days,removethe
batteryandchargeitfully.Eitherstoreitonashelforon
themachine.Leavethecablesdisconnectedifitisstoredon
themachine.Storethebatteryinacoolatmospheretoavoid
quickdeteriorationofthechargeinthebattery.Toprevent
thebatteryfromfreezing,makesureitisfullycharged.The
specicgravityofafullychargedbatteryis1.265-1.299.
CheckingtheFuses
Thefusesarelocatedunderthecontrolpanel.Accessthem
throughthesidepanelcover(Figure49).Toopentheside
panelcover,releasethe2latchesandpulloutonit.
Ifthemachinestopsorhasotherelectricalsystemissues,
checkthefuses.Graspeachfuseinturnandremovethem
oneatatime,checkingtoseeifanyareblown.Ifyouneed
toreplaceafuse,alwaysusethesametypeandamperage
ratedfuseastheoneyouarereplacing,otherwiseyoucould
damagetheelectricalsystem(refertothedecalnexttothe
fuses(Figure50)foradiagramofeachfuseanditsamperage).
Note:Ifafuseblowsfrequently,youprobablyhaveashort
intheelectricalsystemandshouldhaveitservicedbya
qualiedservicetechnician.
Figure49
1.Sidepanelcover
2.Latches
Figure50
43