Service Manual

Table Of Contents
Groundsmaster 7200/7210Page 5 - 12Electrical System
Hour Meter
1. Make sure ignition switch is in the OFF position. Lo-
cate the hour meter and disconnect the wire harness
electrical connector from the meter.
2. Connect the positive (+) terminal of a 12 VDC source
to the positive terminal of the hour meter.
3. Connect the negative (- ) terminal of the voltage
source to the other terminal of the hour meter.
4. The hour meter should move 1/10 of an hour in six
minutes.
5. Disconnect the voltage source from the hour meter.
6. Replace the hour meter if necessary.
7. Connect harness electrical connector to the hour
meter.
Figure 9