Groundsmaster 4100--D/4110--DHydraulic System Page 4 -- 120
3. Place front flange, seal side down, on a flat surface.
4. Install the pressure seals, flat side outward, into the
grooves in the wear plates. Follow by carefully placing
the backup gaskets, flat side outward, between the
pressure seals and the grooves in the wear plate.
5. Applyalightcoating ofpetroleumjellytothe exposed
side of the front flange.
6. Lubricatethedrivegear shaftwithcleanhydraulicoil.
Insert the drive end of the drive shaft through the wear
platewiththepressureseal sidedownandthe openside
of the pressure seal pointing to the inlet side of the mo-
tor. Carefully install shaft into front flange.
7. Lubricate the idler gear shaft with clean hydraulic oil.
Install idler gear shaft into the remaining position in the
front wear plate. Apply a light coating of clean hydraulic
oil to gear faces.
8. Installrear wear plate w ith pressure seal side up and
open side of the pressure seal pointing to the inlet side
of the motor.
9. Apply a light coating of petroleum jelly to new O--ring
and O--r ing groove in the body. Install new O--ring to the
body.
10.Install locating dowel pins in front flange. Align mark-
er line on the body and front flange.
IMPORTANT: Do not dislodge seals during installa-
tion.
11.Gently slide the body onto the assembly. Firm hand
pressure should be sufficient to engage the dowel pins.
12.Installthefour (4)capscrewswithwashersand hand
tighten.
IMPORTANT: Prevent damage when clamping the
fan motor into a vise; clamp on the front flange only.
Also, use a vise with soft jaws.
13.Place front flange of the motor into a vise with soft
jaws and alternately torque the cap screws 33 ft--lb (45
N--m).
14.Remove motor from vise.
15.Placeasmallamountofclean hydraulicoilin theinlet
ofthemotorandrotatethedrive shaftawayfromtheinlet
one revolution. If any binding is noted, disassemble the
motor and check for assembly problems.