Operator's Manual

finger-tight onto the filler neck. Unscrew the the dip-
stick and check the level of oil. If the level is not up to
the FULL mark on the dipstick (Fig. 5), add enough oil
to raise the level to the mark. DO NOT OVERFILL.
3. Screw the dipstick filler cap finger-tight onto the filler
neck.
4. Lower the implement.
The following fluids are recommended for use:
ISO type 46/68 anti-wear hydraulic fluid
Mobil Mobil Fluid
424
Amoco Amoco
1000
International Harvester Hy-
Tran
Texaco
TDH
Shell Donax
TD
Union Oil Hydraulic/Tractor
Fluid
Chevron Tractor Hydraulic
Fluid
BP Oil BP HYD
TF
Boron OIl Eldoran
UTH
Exxon Torque
Fluid
Conoco Power-Tran
3
Kendall Hyken
052
Phillips HG
Fluid
Note: The fluids within this group are interchangeable.
IMPORTANT: Do Not Use Biodegradable Hydraulic
Fluid.
IMPORTANT: Use only types of hydraulic fluids speci-
fied. Other fluids could cause system damage.
Note: A red dye additive for detecting leaks in the
hydraulic system is available in 19.8ml bottles. One
bottle is sufficient for 16–23 l. of hydraulic fluid. Order
Part No. 44-2500 from your Authorized Toro
Distributor
12
Figure 5
1. Dipstick cap
1