Service Manual

HY13-1512-006-M1/USA
Torqmotor™ Service Procedure
TC, TS, TB, TE, TJ, TF, TG, TH and TL Series
Parker Hannifi n Corporation
Hydraulic Pump/Motor Division
Greeneville, TN 37745 US
30
Preparation Before Disassembly
Before you disassemble the Torqmotor™ unit or any of its components read this entire manual. It provides
important information on parts and procedures you will need to know to service the Torqmotor™.
Determine whether the Torqmotor™ you are about to disassemble is the Small Frame Series TC, TS, TB, TE or
TJ or the Large Frame Series TF, TG, TL or TH so you can follow those procedures that pertain to that Series
Torqmotor™. The fi rst two letters of the “spec” number on the Torqmotor™ identifi cation tag is the Series des-
ignation. Also determine the type of end construction from the alternate views shown on the exploded view.
The Small Frame Series TC, TS, TB & TE Torqmotors™ will have a 3.66 inch (92.9 mm) main body outside
diameter and fi ve or six 5/16-24 UNF 2A cover bolts. The Medium Frame Series TJ Torqmotors™ will have a
3.66 inch (92.9 mm) main body outside diameter and six 5/16-24 UNF 2A cover bolts. The Large Frame Series
TF, TG, TL & TH Torqmotors™ will have a 5 inch (127.9 mm) main body outside diameter and seven 3/8 24
UNF 2A cover bolts.
Refer to “Tools and Materials Required for Services” section for tools and other items required to service the
Torqmotor™ and have them available.
Thoroughly clean off all outside dirt, especially from around fi ttings and hose connections, before disconnect-
ing and removing the Torqmotor™. Remove rust or corrosion from coupling shaft.
Remove coupling shaft connections and hose fi ttings and immediately plug port holes and fl uid lines.
Remove the Torqmotor™ from system, drain it of fl uid and take it to a clean work surface.
Clean and dry the Torqmotor™ before you start to disassemble the unit.
As you disassemble the Torqmotor™ clean all parts, except seals, in clean petroleum-based solvent, and blow
them dry.
WARNING: petroleum-base solvents are fl ammable. Be extremely careful when using any solvent. Even a small
explosion or fi re could cause injury or death.
WARNING: WEAR EYE PROTECTION AND BE SURE TO COMPLY WITH OSHA OR OTHER MAXIMUM AIR
PRESSURE REQUIREMENTS.
CAUTION: Never steam or high pressure wash hydraulic components. Do not force or abuse closely fi tted parts.
Keep parts separate to avoid nicks and burrs.
Discard all seals and seal rings as they are removed from the Torqmotor™. Replace all seals, seal rings and
any damaged or worn parts with genuine Parker or OEM approved service parts.
Disassembly and Inspection