Operator's Manual

ElectricalSystem
Maintenance
ServicingtheFuses
Theelectricalsystemisprotectedbyfuses.Itrequires
nomaintenance.Ifafuseblows,checkthecomponent
orcircuitforamalfunctionorshort.
1.Removethecoverunderthecontrolpanel.
2.Pulloutonthefusetoremoveorreplaceit
(Figure30).
3.Installthecoverunderthecontrolpanel.
Figure30
1.Fuse,10amp,bladetype2.Fuse,20amp,bladetype
DriveSystem
Maintenance
AdjustingtheTracking
1.Ifthemachinedoesnottrackstraight,adjustment
isrequired.
2.Checkthereartirepressure.RefertoCheckingthe
TirePressure.
3.Loosenthewingnutsontherightcontrolrodand
rotatetheturnbuckleinorouttoensuretheright
sidecontrolleveriscenteredintheneutrallock
position.Securetheturnbuckleinpositionwiththe
wingnuts(Figure31).
4.Loosenthewingnutsontheleftcontrolrodand
rotatetheturnbuckleinorouttochangethetracking.
Securetheturnbuckleinpositionwiththewingnuts
(Figure31).
5.Checkforpropertracking.Adjusttheleftcontrol
rodifachangeisneeded.
Figure31
1.Turnbuckle
3.Topwingnut(lefthand
threaded)
2.Bottomwingnut
CheckingtheTirePressure
ServiceInterval:Every50hoursormonthly,whichever
occursrst.
Checkthepressureatthevalvestem(Figure32).
Maintaintheairpressureinthereartiresat12-14psi
(83-97kPa).Uneventirepressurecancauseanuneven
cut.
Note:Thefronttiresaresemi-pneumatictiresanddo
notrequireairpressuremaintenance.
29