Service Manual

Briggs
&
Stratton Quantum- Dralnlng Gasoline
1.
Stop the engine and pull the wire off the spark
plug as shown
in
Figure
6.
NOTE: Drain gasoline from a cold engine only.
2.
Turn the fuel shut-off valve,
if
applicable, to the
OFF position
as
shown
in
Figure
IO.
3. Remove the cap from the fuel tank and use a
pump-type syphon to drain the fuel into a clean
gas can.
n
NOTE: This is the only procedure recommended for
draining fuel:
Briggs
&
Stratton Quantum Changing the
Crankcase
Oil
Change the oil after the first
2
operating hours and after
25
hours thereafter. Since warm oil drains better and
carries more contaminants than cold, run the engine
for a minute or
so
before draining oil.
1.
Stop the engine and pull the wire off the spark
plug as shown
in
Figure
6.
2.
Remove the grass bag. Drain gasoline from the
fuel tank; refer to Draining Gasoline, page
20.
3.
Remove the dipstick.
Tip
the mower on its left
side and empty all the oil into a drain pan. See
Figure
11.
Tip
mower down and up a few times
to ensure oil drains completely.
Figure
I
I
4.
After draining,
fill
the engine with
410
cc
(14
oz)
fresh oil. Check the oil level using a dipstick. Fill
to “full” mark,
but
do not overfill.
Briggs
&
Stratton Quantum- Adjusting the Throttle
Throttle control adjustment may
be
required
if
the
engine does not start or stop. Whenever a new throttle
control cable is installed, the throttle must be adjusted.
1.
Stop the engine and
pull
the wire off the spark
2.
Move the throttle control to FAST.
3.
Loosen the cable clamp screw until the throttle
cable slides. See Figure
12.
Align the holes
in
the
throttle lever and throttle bracket using a 3mm
(.121”)
diameter pin. Tighten the cable clamp
plug. See Figure
6.
screw to lock the adjustment
in
place.
THROTTLE CABLE
CLAMP
THROTTLE
LEVER SCREW CABLE
Vacu-Power Mower