Operator's Manual

6.Checkthelevelofthehydraulicuidinthehydraulic
reservoir;refertoCheckingtheHydraulicFluidLevel
(page24).
7.Starttheengineandletitidlefor1or2minutes.
8.Stoptheengine.
9.Checkforleaksaroundthelterarea.
10.Checkthelevelofthehydraulicuidinthehydraulic
reservoir,andadduid,ifnecessary;refertoChecking
theHydraulicFluidLevel(page24).
ChangingtheHydraulic-returnFilter
ServiceInterval:Every500hours
Note:Youcanaccessthehydraulic-returnlterfrom
underneaththerearofthemachine(Figure95).
1.Placeacontainerunderthehydraulic-pressurelter
(Figure95).
Figure95
1.Containersuitablefor
hydraulicuid
3.Hydraulicreturnlter
2.Sharpobject
2.Puncturethebottomofthehydraulic-pressurelter
andallowtheresidualhydraulicuidtodraininthe
container(Figure95).
Note:Useatapered-centerpunchorawltopuncture
theltercase.
3.Rotatethehydraulic-returnltercounterclockwiseand
removethelter(
Figure95).
Note:Discardthelterproperly.
4.Applyathinlayerofthespeciedhydraulicuidto
theO-ringofthenewlter.
Important:Donotusealterstrapwrenchto
tightenthelter.Astrapwrenchcandentthe
lter,causingittoleak.
5.Installthenewlter.
Note:Useyourhandstotightenthelteranadditional
halfturnaftertheltermakescontactwiththelter
head.
6.Checkthelevelofthehydraulicuidinthehydraulic
reservoir;refertoCheckingtheHydraulicFluidLevel
(page24).
7.Starttheengineandrunitatidlefor1or2minutes.
8.Stoptheengineandremovethekey.
9.Checkaroundthelterforleaks.
10.Checktheuidlevelofthehydraulicreservoir,and
adduid,ifnecessary;referto
CheckingtheHydraulic
FluidLevel(page24).
64