Service Manual
7-8 CAMSHAFT/CRANKSHAFT
Breath er
Breather Chamber Cover Removal
•
Remove the bolts [A] and breather chamber cover [B].
Breather Chamber Cover Installation
•
Install a new gasket and the breather chamber cover, and
tighten the bolts.
Breather Valve Inspection
•
Remove the breather valve [A].
•
Inspect the breather valve [ A] for breakage, hair crack or
distortion, replace it if necessary.
•
Inspect the valve seating surface. The surface should be
free of nicks or burrs.
•
Be sure the drain hole on the breather chamber does not
accumulate with slugs before installing the breather valve.