Service Manual
62
62
LUBR
I
CAT
I
NG
SYSTEM
1.
Check valve and valve seat
for
any damage such as crack
or
wear.
2.
Install reed valve
(A)
and back plate
(B)
on inspection
tool
(C),
and check gap between reed valve
(A)
and tool
surface (C) with feeler gauge.
If gap
is
more than
0.2
mm
(0.008
in.). turn over valve
or
replace valve.
EIOFC12WI