Service Manual

37
GTS 200
Rewind
Starter
3. Insert
unknotted end of rope through knot cavity and rope
hole in pulley
.
4.
Thread end of rope through starter housing eyelet and pull
rope until knot is in rope cavity
, Fig. 81.
1
2
Fig. 81 – Inserting Rope
1. Starter
housing eyelet
2.
Pulley rope hole
5. While
holding starter rope handle, slowly let pulley pull
starter rope into starter
.
Install Rewind Starter on Blower Housing
1. If
rewind starter housing was removed from blower
housing, see parts manual for screws and nuts.
Install Blower Housing and Rewind Starter
1. Place
blower housing on engine and start one (1) screw in
extruded hole.
2.
Hold blower housing with extruded hole in recess of
cylinder block, Fig. 82.
1
2
Fig. 82 – Installing Blower Housing
1. Tighten
first
2. T
ighten second
3. Tighten
screw and then install three remaining screws.
Install oil fill tube and dipstick.
Note:
Install fuel tank bracket with blower housing. After
torquing blower housing screws install one (1) screw at top
of fuel tank bracket to top of blower housing and torque
screw to 85 in. lbs. (10.0Nm).
4.
Install oil fill tube and dipstick and torque screw to
45 in. lbs. (5.0Nm).
Note:
The oil fill tube screw is installed on fuel tank
bracket to same torque listed in Step 4.
Install Fuel Tank
1. Install
fuel tank by sliding tank mounting bosses into slots
on fuel tank bracket until tank bottoms in slots.
2.
Start, but do not tighten screws into bottom of fuel tank
bracket.
3.
Install shoulder screw between fuel tank and side tank
mounting boss. Install shoulder screw and torque screw to
85 in. lbs. (10.0Nm), Fig. 83.
21
Fig. 83 – Installing Fuel Tank
1. Torque
screw to 45 in. lbs.
(5.0Nm)
2. T
orque shoulder screw to
85 in. lbs. (9.6Nm)
4. Torque
lower tank mounting screw to 45 in. lbs. (5.0Nm),
Fig. 83.
Note: