Service Manual

Carefree Mower Service Manual 4 - 7
TESTING ELECTRICAL COMPONENTS
Transformer Testing
Test the transformer usin
g
a volt/ohmmeter (Figure 47).
Fi
g
ure 47
0674-008
US & Canadian Models
European, U.K., &
Swiss Models
# Test 24 Volt Models 36 Volt Models
1 Transformer Input Voltage 108 to 132 VAC 108 to 132 VAC 207 - 244 VAC @ 50 hz
2 Transformer Output Voltage* 37.8 to 42.1
VAC*
52.0 to 57.8
VAC*
43.2 VAC*
3 Transformer Primary Resistance 4.5 to 5.3 Ohms 4.6 to 5.4 Ohms 23 - 29 Ohms
4 Transformer Secondary Resistance
(wires removed)
0.6 to 1.0 Ohms 1.2 to 1.6 Ohms 1 - 1.4 Ohms
* Open circuit voltage measured with wires removed and input voltage
at 120 volts A.C.
*Open circuit voltage measured with
wires removed and with the input
voltage at 230 VAC.
NOTE: As the input line voltage varies from normal (120 VAC or 230 VAC) the output will vary accordingly.
#3
#1