Fuse and Circuit Breaker (Fig. 26)
The electrical system is protected by a 30 AMP fuse
located under the control panel and a 20 AMP circuit
breaker with reset button.
NOTE: It is not always possible to see if the fuse is faulty.
It i
s recommended that you check for faulty fuses with
a continuity tester, not visually.
1
2
Figure 26
1. Circuit breaker 2. Fuse
Controller Replacement (Fig. 27)
IMPORTANT: Before welding on the machine, dis-
connect both battery cables from the battery, dis-
connect both wire harness plugs from the controller
and disconnect the terminal connector from the
alternator to prevent damage to the electrical sys-
tem.
1. Stop the engine and disconnect battery cables from
ba
ttery.
2. Disconnect wiring harness connectors from control-
le
r.
3. Remove two (2) nuts securing controller to frame and
re
move controller.
4. Install new controller and secure to frame with nuts
removed in step 3.
5. Connect wiring harness connectors to controller.
6. Connect battery cables.
1
Figure 27
1. Controller
Repairs Page 5 - 28 HydroJect
™