Operator's Manual

4.Installthereserve-tankcap.
Checkingthe
Transaxle/Hydraulic-Fluid
Level
ServiceInterval:Beforeeachuseordaily(checkthe
uidlevelbeforetheengineisrst
startedandevery8hoursordaily,
thereafter.)
Transaxleuidtype:DexronIIIATF
1.Positionthemachineonalevelsurface.
2.Cleantheareaaroundthedipstick(Figure19).
g002376
Figure19
1.Dipstick
3.Unscrewthedipstickfromthetopofthe
transaxleandwipeitwithacleanrag.
4.Screwthedipstickintothetransaxleandensure
thatitisfullyseated.
5.Unscrewthedipstickandchecktheuidlevel.
Note:Theuidshouldbeuptotopoftheat
portionofthedipstick.
6.Ifthelevelislow,addenoughofthespecied
uidtoachievetheproperlevel.
CheckingtheHighFlow
Hydraulic-FluidLevel
TCModelsOnly
ServiceInterval:Beforeeachuseordaily(check
thelevelofhydraulicuidbefore
theengineisrststarted,anddaily
thereafter)
Hydraulic-uidtype:ToroPremiumAllSeason
HydraulicFluid(Availablein5gallonpailsor55
gallondrums.SeepartscatalogorT orodistributorfor
partnumbers.)
Alternateuids:IftheT orouidisnotavailable,
anotherconventionalpetroleum–baseduidmay
beusedprovideditmeetsthefollowingmaterial
propertiesandindustryspecications.Consultwith
yourlubricantdistributortoidentifyasatisfactory
product.
Note:T orowillnotassumeresponsibilityfordamage
causedbyimpropersubstitutions,souseonly
productsfromreputablemanufacturerswhowillstand
behindtheirrecommendation.
HighViscosityIndex/LowPourPointAntiwear
HydraulicFluid,ISOVG46
MaterialProperties:
Viscosity—ASTMD445cSt@40ºC:44to48/cSt
@100ºC:7.9to8.5
ViscosityIndex,ASTMD2270—140to152
PourPoint,ASTMD97—-35ºFto-46ºF
FZG,Failstage—11orbetter
Watercontent(newuid)—500ppm(maximum)
IndustrySpecications:
VickersI-286-S,VickersM-2950-S,DenisonHF-0,
Vickers35VQ25(EatonATS373-C)
1.Cleantheareaaroundthellerneckandthe
capofthehydraulictank(Figure20).
2.Removethecapfromthellerneck.
g010324
Figure20
1.Cap
25