Service Manual

Workman 1100/1110/2100/2110Page 6 – 6Electrical System
Electrical System Quick Checks
Battery Test
Use a multimeter to measure the voltage between the
battery terminals.
Set the multimeter to the DC volts setting. The battery
should be at a temperature of 60
o
to 100
o
F. The ignition
key should be off and all accessories turned off. Connect
the positive (+) meter lead to the positive battery post
and the negative (–) meter lead the the negative battery
post.
NOTE: This test provides a relative condition of the bat-
tery. Load testing of the battery will provide additional
and more accurate information.
Voltage Measured
Battery Charge Level
12.68 V (or higher) Fully charged (100%)
12.45 V 75% charged
12.24 V 50% charged
12.06 V 25% charged
11.89 V 0% charged