6. If valve clearance is not at standard value, loosen
rocker arm locknut and use a feeler gauge to adjust
clearance while turning adjusting screw.
7. Hold screwdriver so adjusting screw will not turn and
tighten locknut to specified torque.
Adjusting screw torque 8 10 Nm (5.8 7.2 ftlb)
Figure 19
8. Turn crankshaft a further 240
in clockwise direction
Ti
and align round mark on camshaft sprocket with timing
mark on timing belt rear cover to set No. 3 cylinder on
compression top dead center.
IMPORTANT: Turn crankshaft only in clockwise
direction.
ming mark
Figure 20
9. Measure valve clearance at locations shown in il-
lustration.
Standard Values mm (in.)
Item When warmed up When cold
(Reference)
Intake valve 0.20 (.008) 0.14 (.006)
Exhaust valve 0.30 (.012) 0.24 (.009)
Figure 21
10. If valve clearance is not at standard value, adjust as
instructed in steps 6 and 7.
Liquid Cooled Gas Engine