Service Manual

Alternator Inspection
1. Check for continuity of rotor coil. Check for continuity
between slip rings. Measure resistance of rotor
. If resis-
tance is low, it indicates a short circuit. If there is no conti-
nuity or a short circuit, replace the rotor assembly.
Resistance standard value 2.8 3.0 Ohms
Figure 105
2. Check rotor coil for ground. Make sure there is no
continuity between slip ring and core. If there is continu-
ity
, replace the rotor assembly.
Figure 106
3. Check stator for continuity. Make sure there is conti-
nuity between coil leads. If there is no continuity
, replace
the stator assembly.
Figure 107
4. Check coil for ground. Make sure there is no continu-
ity between the coil and core. If there is continuity
, re-
place the stator assembly.
Figure 108
Liquid Cooled Gas Engine
Page 3
62
Workman 3000/4000 Series