Service Manual

TestingtheT6:PrechargeController(Model04590)(continued)
4.AccesstheInfoCenterDiagnostics>Precharge>Inputsscreen.
g311218
Figure54
LogicV
If48Vsystemvoltageispresent,theT1:primarycontrollerhasenergized
thelogicrelayandpowerisbeingsuppliedtotheprechargecontroller
prechargeinput(connectorP02pin6).
Ifappears,thecontrollerisnotcommunicatingontheCANbus.
Voltagemustbepresentatthecontrollerlogiccircuit(connectorP03pin6)
beforecommunicationcanoccurontheCANbus.
Ifvoltageisnotpresentatthelogiccircuit,thelogiccircuitfuseor
logiccircuitwiringisdamaged.Thefuseandcircuitwiringshouldbe
checkedforcorrosionordamageandcleaned,repaired,orreplacedas
necessary.
Iflogicvoltageispresentatthecontroller,andCANbuscommunication
issuspect,theCANbuscircuitisdamaged.TheCANbuswiring
shouldbecheckedforcorrosionordamageandcleanedorrepaired
asnecessary.TheprechargecontrollerCANbustransceivercanalso
betestedifnecessary;refertoTestingDevices(Nodes)ontheCAN
bus(page5–32).
If00.0Vispresent,thelogicrelayorlogiccircuitwiringisdamaged.The
relayandcircuitwiringshouldbecheckedforcorrosionordamageand
cleaned,repaired,orreplacedasnecessary.
BusV
If48Vsystemvoltageispresent,themaincontactorhasclosedand
48Vbusvoltageispresentattheprechargecontrollerprechargeoutput
(connectorP02pin3).T oachievethis,theT1:primarycontrollerhas
commandedtheT6:prechargecontrollerviaaCANmessagetoprovidea
pathtoground(prechargecontrollerOUT2)forthe48VDCmaincontactor
coiltoenergizeandclosethemaincontactor.Prechargewassuccessful.
If00.0Vispresent,themaincontactororcircuitwiring(includingthe
prechargecontrollerOUT2circuit)isdamaged.Thecontactorandcircuit
wiringshouldbecheckedforcorrosionordamageandcleaned,repaired,
orreplacedasnecessary.
T6:PrechargeControllerInputs
ElectricalSystem:TestingtheElectricalComponents
Page5–46
Greensmaster®eTriFlex3360and3370
19239SLRevC