Service Manual

Table Of Contents
MachineFaults(continued)
Fault
ID
FaultTitle
Controller(s)
Affected
Fault
Condition/Circuit
Description
AdditionalNotes
ServiceActions
P1A11Battery
Charging
Voltage-High
SC8Thisfaultis
reportedwhen
aLi-ionbattery
cellvoltageis
greaterthan
theallowed
thresholdwhilea
batterycharger
isconnected.
TheLi-ionbattery
controllerwillnot
allowthebattery
tobecharged.
1.Ensurethecorrectchargerisbeing
used.
2.Disconnectthechargerfor5seconds
andthenreconnect.
3.Checkthechargerforfaults.
4.Chargethemachinewithaknown
goodchargerorreplacethecharger.
P1A21Battery
Charging-Over
Current
SC8Thisfaultis
reportedwhen
aLi-ionbattery
cellcharging
currentisgreater
thantheallowed
thresholdwhilea
batterycharger
isconnected.
TheLi-ionbattery
controllerwillnot
allowthebattery
tobecharged.
1.Ensurethecorrectchargerisbeing
used.
2.Disconnectthechargerfor5seconds
andthenreconnect.
3.Checkthechargerforfaults.
4.Chargethemachinewithaknown
goodchargerorreplacethecharger.
5.Checkbatteryandchargerharnesses
forcorrosionordamage.
6.ContactanAuthorizedT oroDistributor
forassistance.
P1B01
Starter/Generator
Motor-High
TempShutdown
T6
Thisfault
isreported
whenthe
starter/generator
motor
temperatureis
greaterthan
130°C(266°
F).
PTOand
starter/generator
isdisabled.
Note:Thisfaultis
notproducedby
abadsensor.
1.Cleantheairintakescreenontheback
ofthestarter/generator.Besurethe
starter/generatorispullingairthrough
theairintakebyfeelingwithyourhand
orbytestingwithapieceofpaper.
2.Letthemachinecool.
3.Reducethecuttingloadsbyreducing
thereelspeedorreducingmowspeed.
4.Ifthefaultcontinues,replacethe
starter/generatormotor.
P1B11
Starter/Generator
Controller-
HighTemp
Shutdown
T6
Thisfault
isreported
whenthe
starter/generator
controller
temperatureis
greaterthan
100°C(212°
F).
PTOand
starter/generator
isdisabled.
Note:Thisfaultis
notproducedby
abadsensor.
1.Cleantheairintakescreenontheback
ofthestarter/generator.Besurethe
starter/generatorispullingairthrough
theairintakebyfeelingwithyourhand
orbytestingwithapieceofpaper.
2.Letthemachinecool.
3.Reducethecuttingloadsbyreducing
thereelspeedorreducingmowspeed.
4.Ifthefaultcontinues,replace
andprogramthestarter/generator
controller(contactanAuthorizedToro
Distributorforassistance).
P1B20
Starter/Generator
MotorSpeed
SensorOutof
Range
T6
Thehalleffect
sensorsinthe
starter/generator
motorprovidean
invalidreading.
Thisfaultwill
notdisable
anymachine
functionality.
1.Checkthewiringbetweenthe
starter/generatormotorandcontroller.
2.Replaceandprogramthe
starter/generatorassembly(contact
anAuthorizedToroDistributorfor
assistance).
P1B21
Starter/Generator
MotorSpeed-
High
T6
Thisfaultis
reportedwhen
thespeedofthe
starter/generator
motorisgreater
than3,600RPM.
1.Checktheenginegovernorifthe
engineRPMisconsistentlyhigh.
2.Checkthewiringbetweenthe
starter/generatormotorandcontroller.
3.Replacethestarter/generatormotor.
Greensmaster®eTriFlex3360and3370
Page3–29
Troubleshooting:BatteryChargerErrorand
FaultCodes(Model04590)
19239SLRevF