Service Manual

Table Of Contents
MachineFaults(continued)
Fault
ID
FaultTitle
Controller(s)
Affected
Fault
Condition/Circuit
Description
AdditionalNotes
ServiceActions
P0A36
Starter/Generator
-Temperature
SensorFailure
T6
Thisfault
isreported
whenthe
starter/generator
FETandthe
motorsensor
fail.
PTOand
starter/generator
isdisabled.
Replaceandprogramthestarter/generator
(contactanAuthorizedT oroDistributorfor
assistance).
P0A3B
Starter/Generator
Motor-High
TempWarning
T6
Thisfault
isreported
whenthe
starter/generator
temperatureis
greaterthan
120°C(248°
F).
Starter/Generator
currentislimited
onalinear
basisuntilthe
temperature
dropsbelow120°
C(248°F)or
exceeds130°C
(266°F).
Note:Thisfaultis
notproducedby
abadsensor.
1.Cleantheairintakescreenontheback
ofthestarter/generator.Besurethe
starter/generatorispullingairthrough
theairintakebyfeelingwithyourhand
orbytestingwithapieceofpaper.
2.Letthemachinecool.
3.Reducethecuttingloadsbyreducing
thereelspeedorreducingmowspeed.
4.Replacethestarter/generatormotor.
P0A3C
TractionMotor
Controller-High
TempWarning
SC5,SC6,
T5
Thisfaultis
reportedwhen
thetemperature
isgreaterthan
90°C(194°F)
intheindicated
tractionmotor
controller.
Tractionmotor
currentislimited
onalinear
basisuntilthe
temperature
dropsbelow
90°C(194°F)
orexceeds100°
C(212°F).
1.Reducethegroundspeed.
2.Checkformechanicalresistanceinthe
wheelsthatwouldmakethemotors
workextrahard.
3.ForSC5andSC6:Replaceand
programthetractionmotorcontroller
(contactanAuthorizedToroDistributor
forassistance).
ForT5;Replaceandprogramthe
tractionmotorassembly(contact
anAuthorizedToroDistributorfor
assistance).
4.Cyclethekeyswitch.
5.UsetheInfoCentertocalibratethe
tractionmotorcontroller.
ForSC5,calibratethetractionpedal
rst,thenthetractionmotors.
ForSC6,calibratethetractionmotors.
P0A3E
Starter/Generator
Controller-
HighTemp
Warning
T6
Thisfault
isreported
whenthe
starter/generator
controller
temperatureis
greaterthan90°
C(194°F).
Starter/Generator
currentislimited
onalinear
basisuntilthe
temperature
dropsbelow90°
C(194°F)or
exceeds100°C
(212°F).
Note:Thisfaultis
notproducedby
abadsensor.
1.Cleantheairintakescreenontheback
ofthestarter/generator.Besurethe
starter/generatorispullingairthrough
theairintakebyfeelingwithyourhand
orbytestingwithapieceofpaper.
2.Letthemachinecool.
3.Reducethecuttingloadsbyreducing
thereelspeedorreducingmowspeed.
4.Replaceandprogramthe
starter/generatorcontroller(contact
anAuthorizedToroDistributorfor
assistance).
Troubleshooting:BatteryChargerErrorandFaultCodes
(Model04590)
Page3–20
Greensmaster®eTriFlex3360and3370
19239SLRevF