Service Manual

Table Of Contents
MachineFaults(continued)
Fault
ID
FaultTitle
Controller(s)
Affected
Fault
Condition/Circuit
Description
AdditionalNotes
ServiceActions
P1B6CStarter/Generator
Internal
Hardware
Failure
T6
Thisfault
isreported
whenthe
hardwarephase
overcurrent
andhardware
overvoltagetrip.
PTOand
starter/generator
isdisabled.
1.Cyclethekeyswitch.
2.Ifthefaultrepeats,replaceand
programthestarter/generator
controller(contactanAuthorizedToro
Distributorforassistance).
P210ETractionPedal1
Sensor/Switch
Analogvs
Analogconict
SC5Thisfaultis
reportedwhen
thetraction
pedalsensors
reportdifferent
positions.
Tractionis
disabled.
1.UsetheInfoCenterDiagnostics>
Traction>Inputsscreentoobserve
thetractionpedalpositionsensor
operation.
2.Checkthewiringtothesensor
connector(P36).
3.CheckthesensorwiringtotheT1:
primarycontroller(P01).
4.Replacethetractionpedalposition
sensor.
5.UsetheInfoCentertocalibratethe
tractionpedal.
P2503Alternator-
ChargingT oo
Low
Note:The
alternator
consistsof
astatorcoil,
ywheel
magnets,and
anexternal
voltage
regulator
T1
Thisfaultis
reportedwhen
theTECsenses
thatthe12V
chargingsystem
islessthan8.8V.
PTOisdisabled.1.Testthe15Aminibladestylefusein
the12Vfuseholder(undertheright
sidecover).
2.Testthecircuitwiringandconnector
(P70).
3.Testthevoltageregulator.The
regulatoroutputtobatteryshouldbe
approx.15VDCat2,400RPM.
4.Testthealternator.Thealternator
outputtotheregulatorshouldbe
approx.21VACat2,400RPM.
5.SwaptheT1:Primarycontroller
withaknown-goodunit(contact
anAuthorizedToroDistributorfor
assistance).
P2504Alternator-
ChargingT oo
High
Note:The
alternator
consistsof
astatorcoil,
ywheel
magnets,and
anexternal
voltage
regulator
T1
Thisfaultis
reportedwhen
theTECsenses
thatthe12V
chargingsystem
isgreaterthan
16.3V.
1.Testthecircuitwiringandconnector
(P70).
2.Testthevoltageregulator.The
regulatoroutputtobatteryshouldbe
approx.15VDCat2,400RPM.
3.Testthealternator.Thealternator
outputtotheregulatorshouldbe
approx.21VACat2,400RPM.
4.SwaptheT1:Primarycontroller
withaknown-goodunit(contact
anAuthorizedToroDistributorfor
assistance).
P2530
KeyStart/On
Correlation
Fault
T1
Thisfaultis
reportedwhen
thekeystart
inputisactive
butthekeyOn
inputisoff.
Machinewill
shutdownsince
keyOninputis
inactive
1.UsetheInfoCenterDiagnostics>
Engine>InputstoverifythekeyOn
andkeystartcircuitinputs.
2.Checkthekeyswitchcircuitwiringand
connectors(P57,P01).
3.Testthekeyswitch.
Greensmaster®eTriFlex3360and3370
Page3–31
Troubleshooting:BatteryChargerErrorand
FaultCodes(Model04590)
19239SLRevE