Operator's Manual

Lubrication
GreasingtheGeneratorBelt
Tensioner
ServiceInterval:Every400hours
LubricatethegreasettingregularlywithNo.2General
PurposeLithium-BaseGrease.
1.Wipethegreasettingcleansoforeignmattercannot
beforcedintothebearingorbushing(Figure43).
g016344
Figure43
Thegreasettingislocatedbehindtheseatontheinner,
rightsideofthemachine.
2.Pumpgreaseintothebearingorbushinguntilthe
greaseisvisible.Wipeupexcessgrease.
EngineMaintenance
ServicingtheAirCleaner
ServiceInterval:Every200hours
Checktheaircleanerbodyfordamagewhichcouldcause
anairleak.Replaceifdamaged.Checkthewholeintake
systemforleaks,damageorloosehoseclamps.
Servicetheaircleanerlterbefore200hoursifthe
engineperformancesuffersduetoextremelydusty,dirty
conditions.Changingtheairlterbeforeitisnecessary
onlyincreasesthechanceofdirtenteringtheenginewhen
thelterisremoved.
Besurethecoverisseatedcorrectlyandsealswiththe
aircleanerbody.
1.Releasethelatchessecuringtheaircleanercovertothe
aircleanerbody(
Figure44).
g014614
1
2
3
Figure44
1.Aircleanerbody3.Aircleanercover
2.Airlter
2.Removethecoverfromtheaircleanerbody.Before
removingthelter,uselowpressureair(40psi,clean
anddry)tohelpremovelargeaccumulationsofdebris
packedbetweenoutsideofprimarylterandthe
canister.Avoidusinghighpressureairwhichcould
forcedirtthroughthelterintotheintaketract.This
cleaningprocesspreventsdebrisfrommigratinginto
theintakewhentheprimarylterisremoved.
3.Removeandreplacetheprimarylter.Cleaningofthe
usedelementisnotrecommendedduetothepossibility
ofdamagetotheltermedia.Inspectthenewlterfor
shippingdamage,checkingthesealingendofthelter
andthebody.Donotuseadamagedelement.Insert
thenewlterbyapplyingpressuretotheouterrimof
theelementtoseatitinthecanister.Donotapply
pressuretotheexiblecenterofthelter.
36