Service Manual

Greensmaster 3300/3400Hydraulic System Page 5 − 98
Lift Control Manifold Service
1. Lift manifold
2. Zero leak plug (5 used)
3. Orifice (0.028) (ports C4 and C6)
4. 90
o
fitting
5. Solenoid valve (port S2)
6. Solenoid valve (port S4)
7. Solenoid coil
8. Nut
9. Solenoid coil (3 used)
10. Coil spacer
11. Nut
12. Relief valve (port RV)
13. Solenoid valve (port S1)
14. Solenoid valve (port S3)
15. Check valve (port CV)
16. 45
o
fitting
17. Orifice (0.037) (port C2)
25 ft−lb
(34 N−m)
60 in−lb
(6.7 N−m)
20 ft−lb
(27 N−m)
UP
VIEW FROM
BELOW
Figure 71
2
6
8
9
10
11
13
1
5
7
12
14
15
16
4
2
2
3
8
9
9
10
17
3
20 ft−lb
(27 N−m)
20 ft−lb
(27 N−m)
60 in−lb
(6.7 N−m)
20 ft−lb
(27 N−m)
20 ft−lb
(27 N−m)