Leak Detector
Operation
The leak detector system is designed to assist in the ear-
FILLER CAP
ly detection of hydraulic oil system leaks. If the oil level
in the main tank is lowered by 4 to 5 ounces, the level
switch in the leak detection tank will close. After a 1 se-
cond delay, the alarm will sound alerting the operator.
Expansion of oil from the normal heating of the hydraulic
oil during machine operation will cause oil to transfer into
the leak detection tank. The oil is allowed to return to the
main tank when the ignition switch is turned off (see Fig.
20, 21, and 22).
ÉÉÉ
ÉÉÉ
ÉÉ
ÉÉ
ÉÉ
ÉÉ
FLUID LEVEL
COLD
SOLENOID
RETURN
OPEN
SIGHT
WINDOW
NO SOUND
VALVE
FLOAT RAISED
SWITCH OPEN
BEFORE START (oil cold)
Figure 20
ÉÉ
ÉÉ
ÉÉ
ÉÉÉ
ÉÉÉ
ÉÉ
SWITCH OPEN
NO SOUND
FLUID LEVEL
SOLENOID
RETURN
CLOSED
NORMAL OPERATION (oil warm)
FLOAT RAISED
WARM
VALVE
Figure 21
LEAK ALERT!
ÉÉ
ÉÉÉ
ÉÉ
FLUID LEVEL
SOLENOID
RETURN
CLOSED
BUZZER
SOUNDS
FLOAT DOWN, SWITCH CLOSED
(FLUID LEVEL DOWN 4 TO 5 OUNCES)
WARM
VALVE
WARNING
Figure 22
Electrical
System
Greensmaster 3200/3200–D
Page 6 – 29
Electrical System