Operator's Manual

Incor r ect batter y ca ble r outing could
dama ge the tractor and ca bles causing
spar ks. Spar ks can cause the batter y gasses
to explode, r esulting in per sonal injur y .
Al w ays disconnect the negati v e (black)
batter y ca ble bef or e disconnecting the
positi v e (r ed) ca ble.
Al w ays connect the positi v e (r ed) batter y
ca ble bef or e connecting the negati v e
(black) ca ble.
Note: Chec k batter y condition w eekly or after
ev er y 50 hours of operation. K ee p ter minals and
entire batter y case clean because a dir ty batter y will
disc harg e slo wly . T o clean the batter y , w ash the
entire case with solution of baking soda and w ater .
Rinse with clear w ater . Coat the batter y posts and
cable connectors with Grafo 112X (skin-o v er)
g rease (T oro P ar t No . 505-47) or petroleum jelly
to prev ent cor rosion.
Batter y electr ol yte contains sulfuric acid
which is a deadl y poison and causes sev er e
bur ns.
Do not drink electr ol yte and a v oid
contact with skin, ey es or clothing . W ear
safety g lasses to shield y our ey es and
r ub ber g lo v es to pr otect y our hands.
Fill the batter y wher e clean w ater is
al w ays a v aila ble f or flushing the skin.
Fuses
T here are 7 fuses in the mac hines electrical system.
T hey are located belo w the operators control panel
( Figure 49 and Figure 50 ).
Figure 49
1. Fuses
Figure 50
Optional Lighting
Important: If optional lighting is be added
to the traction unit, use the instr uctions,
schematic ( Figur e 51 ), and par t n umber s
listed belo w to pr ev ent dama ge to the traction
units electrical system.
Installation Instructions
1. Install a rela y into the open connector under
console .
2. Install light switc h.
Note: Punc h out in control panel pro vided
for switc h installation.
3. Crimp a ring or fork ter minal onto eac h of
the orang e wires (J 24 & J 25) under console .
Secure them to light switc h ter minals #2 & #3.
4. Splice po w er (+) wires from lights to red wire
at J 23.
40