Operator's Manual

Figure25
1.Backlapknobs2.Reelcontrolknobs
ReelSpeedControls
ControlsRPMoffrontandrearcuttingunits(Figure25).
#1positionisforbacklapping.Remainingsettingsare
formowingoperations.Seedecalunderseatforproper
settings.
Seat
Theseatadjustinglever(Figure26)allows4inchfore
andaftadjustment.Theseatadjustingknob(Figure26)
adjustsseatforoperatorsweight.Toadjustseatfore
andaft,pullleveronleftsideofseatassemblyoutward.
Aftermovingseattodesiredlocation,releaseleverto
lockseatintoposition.Toadjustforoperatorsweight,
turnspringtensionknob;clockwisetoincreasetension,
counterclockwisetodecreasespringtension.
Figure26
1.Seatadjustinglever2.Seatadjustingknob
GreenDiagnosticLight
Themachineisequippedwithadiagnosticlightwhich
indicatesiftheelectroniccontrollerisfunctioning
correctly.Thegreendiagnosticlight(Figure27)is
locatedunderthecontrolpanel,nexttothefuseblock.
Whentheelectroniccontrollerisfunctioningcorrectly
andthekeyswitchismovedtotheONposition,the
controllerdiagnosticlightwillbeilluminated.Thelight
willblinkifthecontrollerdetectsamalfunctionin
theelectricalsystem.Thelightwillstopblinkingand
automaticallyresetwhenthekeyswitchisturnedtothe
OFFposition.
Figure27
1.Greendiagnosticlight
Whenthecontrollerdiagnosticlightblinks,oneofthe
followingproblemshasbeendetectedbythecontroller:
Oneoftheoutputshasbeenshorted.
Oneoftheoutputsisopencircuited.
Usingthediagnosticdisplay,determinewhichoutput
ismalfunctioning,refertoCheckingInterlock
Switches.
Ifthediagnosticlightisnotilluminatedwhenthe
keyswitchisintheOnposition,thisindicatesthat
theelectroniccontrollerisnotoperating.Possible
causesare:
Loopbackisnotconnected.
Thelightisburnedout.
Fusesareblown.
Nobatterypower.
Checkelectricalconnections,inputfusesand
diagnosticlightbulbtodeterminemalfunction.
Makesureloopbackconnectorissecuredtowire
harnessconnector.
DiagnosticACEDisplay(Optional)
Themachineisequippedwithanelectroniccontroller
whichcontrolsmostmachinefunctions.Thecontroller
23