ChargingtheBattery(continued)
6.Threehoursbeforetheendofthecharging,measurethespecicgravityofa
batterycellonceperhour.
Note:Thebatteryisfullychargedwhenthecellsaregassingfreelyata
lowchargingrateandthereislessthana0.003changeinspecicgravity
for3consecutivereadings.