TestProcedure(continued)
3.Fortheliftcylinderthatistobetested,useajacktoraisetheliftarmslightly.
Thiswillremovetheloadfromtheliftcylinderandrelieveliftcylinderhydraulic
pressure.Leavethejackundertheliftarmtosupporttheliftarmandto
preventtheliftarmfromlowering.
Note:Ifeitheroftherearliftcylindersisbeingtested,bothrearliftarms
needtobesupported.
g230047
Figure106
1.Liftcylinder(#5)2.Cylinderrodendtting
3.Hydraulichose
4.Cleantheareaaroundtheendofthehydraulichoseattherodendofthelift
cylinderforthesupportedliftarm.Disconnectthehydraulichosefromthelift
cylinderrodendtting(Figure106).
IMPORTANT
Whencappingliftcylinderttingandhydraulichoseend,useasteel
capandplugtoensurethattheuidleakagewillnotoccur.Plastic
plugswillnotholdhydraulicpressurethatwillbedevelopedduring
thistestprocedure.
5.Placeasteelcapontheopenliftcylinderttingtosealtheliftcylinder.Also,
installasteelplugintheopenendofthedisconnectedhosetoprevent
leakageorcontamination.
6.Slowlylowerthejackandremoveitfromundertheliftarm.Thecuttingunit
shouldsettleslightlyandthenbesupportedbythecappedliftcylinder.
Reelmaster
®
5410/5510/5610Series
Page6–93
HydraulicSystem:TestingtheHydraulicSystem