Service Manual

Reelmaster 5010 Series
DPA Cutting Units
Page 7 20
Bedknife Replacement and Grinding
Bedknife Removal
1. Remove bedbar from cutting unit (see Bedbar As-
sembly in this chapter).
2. Remove screws from bedbar using a socket wrench
and bedknife screw tool (see Special Tools in this
chapter). Discard screws. Remove bedknife from the
bedbar (Fig. 26).
3. See bedknife grinding information on the following
pages.
Bedknife Installation
1. Use scraper to remove all rust, scale and corrosion
from bedbar surface. Lightly oil bedbar surface before
installing bedknife.
2. Make sure that screw threads in bedbar
(5/1618UNC2A) are clean.
IMPORTANT: Do not use an impact wrench to tight-
en screws into the bedbar.
3. Use new screws to secure bedknife to bedbar. Apply
antiseize lubricant to the threads of new screws. Do not
apply antiseize lubricant to the taper of the screw heads.
4. Install all screws but do not tighten.
5. Using a torque wrench and bedknife screw tool,
tighten the 2 outer screws to 10 inlb (1 Nm).
6. Working from the center of the bedknife toward each
end (Fig. 27), tighten screws from 200 to 250 inlb (23
to 28 Nm).
7. After installing bedknife to bedbar, grind bedknife.
1
2
3
Antiseize
Lubricant
Lightly Oil
Bedbar Surface
200 to 250 inlb
(23 to 28 Nm)
1. Screw (8 used)
2. Bedbar
3. Bedknife
Figure 26
346810579
12
# TOR510880
2nd 200 to 250 inlb (23 to 28 Nm)
1st 10 inlb (1 Nm)
Figure 27