Service Manual

AssemblingthePiston(Traction)PumpControlAssembly(continued)
g213686
Figure147
1.Tractionpump2.Pumplever3.Tractionneutralswitch
2.Ifthetractionneutralswitchwasremovedfromthepumpplate,adjustthe
locationoftheswitchsothatthereis2.4to2.5mm(0.094to0.100inch)
clearancebetweentheheadoftheneutralswitchandthetractionpumplever
(Figure147);refertotheTractionNeutralSwitch(page7–46)foradditional
neutralswitchinformation.
3.Afterthetractionpumpcontrolassemblyhasbeeninstalled,ensurethat
thetractioncontrolassemblyisadjustedfortheneutralpositionsothatthe
machinedoesnotmoveorcreepwhenthetractionpedalisinneutral;refer
totheTractionUnitOperator’sManual.
HydraulicSystem:ServiceandRepairs
Page6–158
Reelmaster
®
5410/5510/5610Series
15216SLRevD