Service Manual

Table Of Contents
ServiceScreen(continued)
PTOStartsidentiesthenumberoftimesthatthereelengageswitchhas
beenengaged.
TapOffs
DPFRegeneration(PINrequired)allowstheoperatorortechniciantoinitiate
aparked(stationary)dieselexhaustparticulatelter(DPF)regenerationon
machineswithYanmarTier4Fcompliantengines.Theparked(stationary)
regenerationiconwillappearintheInfoCenterdisplayandtheenginepower
willbede-ratedto85%whenaparked(stationary)regenerationisnecessary.
Donotcontinuetooperatethemachineinanormalmannerwhenaparked
(stationary)regenerationrequestappears.Performaparked(stationary)
regenerationassoonaspossible;refertothetractionunitOperator’sManualfor
additionalinformationandparked(stationary)regenerationproceduresspecic
toyourmachine.
MovethemachinetoawellventilatedareaandinitiateastationaryDPF
regenerationbypressingtheleft/rightbutton(asindicatedbythe
atthe
bottomofthescreen)andthenpressingthedownbutton(asindicatedbythe
Yesor
atthebottomofthescreen).Additionalinformationcanbefoundin
theYanmarEngineServiceManual.
DPFAsh(PINrequired)DPFashisthelevelofashaccumulatedintheDPF
(diesel-particulatelter)onthemachineswithYanmardieselengines.Ash
isthebyproductofperformingnumerousregenerationoperations.Anengine
faultwillbegeneratediftheashaccumulationexceeds50g/l.Ifexcessiveash
accumulationlevelsexist,DPFreplacementmaybenecessary.
DiagnosticsScreen
g189672
Figure210
1.Diagnosticsmenu
4.Menu/backbutton
2.Left/rightbutton
5.Diagnosticsitems
3.Downbutton
Thediagnosticsscreen(Figure210)listsavarietyofmachineoperationsand
thecurrentstateoftheT oroElectronicController(TEC)inputs,qualiers,and
outputsrequiredtoallowtheoperationtoproceed.Thediagnosticsscreen
shouldbeusedtotroubleshootmachineoperationissues,andcheckthat
Reelmaster
®
5410/5510/5610Series
Page7–19
ElectricalSystem:InfoCenterDisplay
15216SLRevE