Service Manual
Reelmaster 5010 Series Page 4 - 73
NOTE: For piston (traction) pump repair information,
see the Sauer- Danfoss LPV Closed Circuit Axial Piston
Pumps Repair Manual and Service Instructions at the
end of this chapter.
IMPORTANT: If a piston (traction) pump failure oc-
curred, refer to Traction Circuit Component Failure
in the General Information section for information
regarding the importance of removing contamina-
tion from the traction circuit.
Three ( 3) styles of traction control assemblies have
been used on Reelmaster 5010 machines. Machines
with a serial number below 310000000 use traction con-
trol components as shown in Fig. 62. Machines with a
serial number from 310000001 to 310999999 include
control components that are shown in Fig. 63. Machines
with a serial number above 3110000001 use control
components that are shown in Fig. 64.
Figure 63
1. Piston (traction) pump
2. Screw
3. Pump control arm
4. Cap screw
5. Lock nut
6. Cap screw
7. Traction lever bracket
8. Cap screw (4 used)
9. Pump plate
10. Jam nut (2 used)
11. Lock washer (2 used)
12. Neutral switch
2
3
4
5
1
6
7
9
8
10
11
12
10
11
1. Piston (traction) pump
2. Lock nut
3. Carriage screw
4. Pump lever
5. Jam nut (2 used)
6. Lock washer (2 used)
7. Neutral switch
8. Cap screw (3 used)
9. Pump plate
Figure 64
1
2
3
4
5
6
7
9
8
5
Hydraulic System