Service Manual

Table Of Contents
BatteryCare(continued)
WARNING
Connectingthecablestothewrongbatterypostcouldresultin
personalinjuryand/ordamagetotheelectricalsystem.
Ensurethatthecablesareproperlyconnectedtothecorrectbattery
postsbeforeoperatingthemachine.
4.Ifcorrosionoccursatthebatteryterminals,disconnectthecables.Always
disconnectthenegative(-)cablerst.Cleanthecableclampsandterminals
separately.Connectthecableswiththepositive(+)cablerst.Applyalayer
ofterminalprotector(ToroPartNo.107-0392)oralightcoatofpetroleum
jellytotheterminalstoreducecorrosionafteryoumaketheconnections.
5.Checkthebattery-electrolytelevelevery25operatinghoursandevery30
daysifmachineisinstorage.
6.Maintainthecelllevelwiththedistilledordemineralizedwater.
Note:Donotllthecellsabovethellline.
ServicingtheBattery
Thebatteryistheheartoftheelectricalsystem.Withtheregularandcorrect
service,thebatterylifecanbeextended.Additionally,thebatteryandelectrical
componentfailurecanbeprevented.
CAUTION
Battery-electrolyteiscorrosiveandcanburnskinandeyesand
damageclothing.
Whileworkingwiththebatteries,useextremecautiontoavoid
splashingorspillingoftheelectrolyte.Alwayswearthesafety
gogglesandafaceshieldwhileworkingwithbatteries.
BatterySpecications
Battery-electrolytespecicgravityFullyCharged:1.250to1.280
Discharged:lessthan1.240
BatteryspecicationsBCIGroupSize:55
585CCAat-18°C(0°F)
ReserveCapacityof75minutesat27°C(80°F)
Batterydimensions(includingterminalposts
andcaps)
Length23.1cm(9.1inches)
Width15.2cm(6.0inches)
Height21.6cm(8.5inches)
Reelmaster
®
5410/5510/5610Series
Page7–125
ElectricalSystem:ServiceandRepairs
15216SLRevE