Service Manual
Servicing the Bedknife/Bedbar Assembly
NOTE: The bedbar on each 335-D cutting unit has a
precision ground mounting surface to provide an excel-
lent fit with a bedknife. Backlapping of replacement
bedknives is often sufficient to achieve an excellent
cutting edge with minimum material removed.
Bedknife/Bedbar Removal:
1. Remove the shoulder bolts,bushings and spacers
f
rom each end of the unit and remove the bedbar/bed-
knife assembly (Fig. 16).
2. Remove the mounting screws for the bedknife and
sep
arate the bedknife from the bar (Fig. 17). Discard the
screws.
Assembly:
1. Thoroughly clean the bedknife mounting face on the
be
dbar of all rust and scale. Remove any material on
the mounting face of the bedbar that will affect a good
match-up with the bedknife.
2. Before installation, apply a coating of “Never Seez”,
or
any material that will ease future disassembly of the
bedknife mounting screws, to the threads before instal-
lation.
3. Use a torque wrench and special bedknife screw tool
to c
omplete tightening of the screws (Fig. 18). Tighten
the screws to a torque of 250 in.-lb (28 Kgm) beginning
with the center screw and tightening alternate screws
toward each end to insure the bedknife will be flat
against the bedbar.
4. Install the bedbar/bedknife assembly to the cutting
un
it.
Figure 16
1. Shoulder bolts (2 each side) 2. Bushing 3. Spacer
Figure 17
1. Bedbar 3. Bedknife mounting screws
2. Bedknife 4. Bedbar mounting components
Figure 18
1. Torque wrench
2. Part No. 51-0880 Tool
3. Torque from the center out
Repairs Page 7 - 12 Reelmaster
®
335-D