Service Manual

Nozzle Leakage Test
A nozzle that leaks fuel from the nozzle orifice must be
r
eplaced.
1. Securely fasten the nozzle to the adapter.
2. Wipe all fuel from the nozzle.
3. Operate the pump until the pressure is approximately
20 bar or kg/cm
2
(280 psi) below opening pressure.
Maintain this pressure to the nozzle.
4. Watch for leaks where the threaded nozzle body
threads into the retaining nut. Leaks in this area would
indicate a bad seat between the distance piece and/or
the body or nozzle assembly.
5. If leakage occurs, verify that the body is tightly fas-
t
ened in the retaining nut. If the leak continues, replace
the nozzle.
6. While pressure is being applied, watch for an ac-
c
umulation of fuel at the tip of the nozzle (Fig. 35). A
small amount of fuel may be present due to a previous
chattering test - this would be normal. If the fuel accumu-
lates and drips down during the test (about ten seconds)
the nozzle assembly is defective and must be replaced.
Spray Test
For proper combustion, the nozzle must effectively
at
omize the injected fuel.
1. Operate the pump handle quickly (4 - 6 strokes per
s
econd).
2. Observe the injector nozzle spray. The spray pattern
should be finely atomized in a broad, straight stream
(Fig. 36).
3. If the nozzle fails to spray properly, it must be cleaned,
r
epaired or replaced.
Good Bad Bad
Figure 35
Good Bad Bad
broad spray narrow spray angled spray
fine mist streaky mist
straight
Figure 36
Engine Page 3 - 30
Rev
. B
Reelmaster 335-D/3500-D