Cutting Unit Operation Problems (continued)
Condition Possible Cause Correction
No cutting units engage. Axle in Hi range.
Axle must be in Low range for cut-
ting units to operate.
“Reel” fuse open.
Check fuse and replace if fuse is
open. If fuse burns out often, find
and correct cause.
Cutting unit relay faulty.
Test relay. Replace relay if faulty.
Cutting unit relay wiring loose, cor-
Repair wiring.
roded or damaged.
Transaxle shift linkage out of ad-
Check linkage and adjust if nec-
justment (not closing Hi/Low switch
essary.
in Low range).
Axle Hi/Low switch faulty.
Test switch. Replace if faulty.
Make sure switch is screwed all
the way in.
Axle Hi/Low switch wiring loose,
Repair wiring.
corroded or damaged.
PTO switch faulty.
Test switch. Replace if faulty.
PTO switch wiring loose, corroded
Repair wiring.
or damaged.
Variable reel control in neutral (N)
Check control and linkage. Adjust
position or linkage out of
linkage if necessary.
adjustment..
Variable reel control switch faulty.
Test switch. Replace if faulty.
Make sure switch is screwed all
the way in.
Variable reel control switch wiring
Repair wiring.
loose, corroded or damaged.
Problem not electrical.
See Troubleshooting section in
Chapter 4 - Hydraulic System.
Reelmaster
®