Service Manual

Standard Control Module
The Reelmaster 2000–D is equipped with a Standard
Control Module to monitor and control electrical compo-
nents required for safe operation. This Module is at-
tached to the back of the instrument panel (Fig. 19).
Inputs from the neutral, parking brake, PT
O, start (igni-
tion), backlap, and high temperature switches are moni-
tored by the Module. Output to the PTO (reel drive
solenoid), electric starter motor
, and engine run sole-
noid are controlled based on the inputs received by the
Module.
The Standard Control Module does not connect to an
external computer or hand held device, can not be re–
programmed, and does not record intermittent fault
data.
The Standard Control Module can be used
to check op-
eration of machine switches by monitoring the LED of
t
he module. If a Module LED does not illuminate (e.g. the
in seat input LED does not illuminate with the seat occu-
pied and the ignition switch in the run position), testing
of the switch and circuit wiring would be required.
Refer to the Traction Unit Operator’s Manual for opera-
tion and troubleshooting of the Standard Control Mod-
ule.
2
1
Figure 19
1. Instrument panel 2. Standard control module
1
2
3
4
5
6
7
8
9
10
11
Figure 20
1. Power input LED 6. Neutral input LED
2. Start input LED 7.
Park brake off input LED
3. Engine run output LED 8.
PTO switch input LED
4. Start output LED 9.
In seat input LED
5. PTO output LED 10.
High temp input LED
11. Backlap input LED
Electrical System
Page 5 – 18
Reelmaster 2000–D